Horizontal Cylinderical Autoclave

HORIZONTAL CYLINDRICAL AUTOCLAVE HIGH SPEED is based on the principle that microbiological action of saturated steam at elevated temperature is rapid and through. All models work on the principle of downward displacement of air which is the most economical method of obtaining sterilization. Robust and rigid construction, designed for all types of bulk sterilization which are commonly needed in Medical, Agricultural, research Institute and Pharmaceutical Industries. Suitable for Sterilizing hospital dressings, rubber, plastic goods, surgical instruments, glass wares, etc.

Construction: Triple walled with steam jacket and separate boiler Inner chamber and steam jacket are made up of Heavy gauge S.S. 316/304 Sheet with leak proof argon-arc welding. The sterilizer has single piece door made of stainless steel 316/304. Back plate and ring is also made of thick stainless steel sheet. All the sterilizers are hydraulically tested to withstand 2.5kg/cm2 times the working pressure. Mounted on tubular steel frame with ground leveling screwed flanges. The Outer jacket is wrapped with asbestos sheet or glass wool to minimize the heat losses due to radiation and is covered by polished stainless steel sheet for that elegant appearance.

Steam Generator Made of heavy stainless steel sheet. Heavy ring mounted in front of the boiler with folding thick stainless steel plate is fitted with heating elements and low water level cutoff device to protect the former from burning out dry. Front folding plate system provides for easy cleaning of the deposited scale on the elements and the walls for long life and efficiency. Fitted with water gauge glass for water level indication, water inlet and outlet valves Control Panel Switch Box To provide electrical control panel box and mounted on the stand of the sterilizer for easy operation. Electrical parts-pressure switch, contactor, water level relay, MCB, YBR Indicators, & on off switch.

Other Features Triple Safety: - The Sterilizer is provided with the triple safety features. At the boiler level by a Piezostat which automatically limits the pressure to the required set value and a spring loaded safety valve in case of its failure which releases the steam to keep pressure within the safety limits. At the chamber level, a spring loaded safety valve and a dead weight release valve to release the steam in case the pressure exceeds the safety limit. All these safety features function independent of one another and sequentially i.e. one take over the charge in case of other's failure.

Prevents the discharge line from choking. The plug is easily removable for daily cleaning.

Prevents the discharge line from choking. The plug is easily removable for daily cleaning. air throughout the chamber. The circulating air passes through a corrosion resistant metallic wool filter.

Digital Display is provided to show the chamber temperature.

Automatic Vacuum breaker is provided to break vacuum in case of formation of vacuum due to steam condensation.

Operating Temp. & Pressure
Working Temp: 121°C to 134°C
Working pressure: 1.2 to 2.2 kg/cm2 (15 psi to 30psi) Hydro test - 4 kg/cm2
Power Requirement: Suitable to operate on 440V volts, 3 ph, 50 Hz, Ac supply

Optional Features
Chamber/Jacket of S.S. 316/304
Door of S.S. 304/316
Dressing Drums
Direct steam supply from centralized boiler
Digital Temperature controller
High pressure High vacuum model
Additional Single door/ (Double door) model
Fully automatic PLC & HMI with printer/ microprocessor base controlled mod